P500-3
Specifications
The new 350 – 750 kVA industry leading power range is the result of a continued focus on performance, durability and serviceability combined with the most advanced production methods to deliver power you can trust.
Generator Set Specifications
Minimum Rating | 450.0 kVA / 360.0 kW 450.0 kVA / 360.0 kW | More |
Maximum Rating | 500.0 kVA / 400.0 kW 500.0 kVA / 400.0 kW | More |
Voltage | 220-415 Volts 220-415 Volts | More |
Frequency | 50 Hz or 60 Hz 50 Hz or 60 Hz | More |
Speed | 1500 or 1800 RPM 1500 or 1800 RPM | More |
50 Hz Prime | 450.0 kVA / 360.0 kW 450.0 kVA / 360.0 kW | More |
50 Hz Standby | 500.0 kVA / 400.0 kW 500.0 kVA / 400.0 kW | More |
60 Hz Prime | – / – – / – | More |
60 Hz Standby | – / – – / – | More |
Generator Set Configurations
Emissions/Fuel Strategy | Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. | More |
Engine Specifications
Engine Model | Perkins® 2506A-E15TAG1 Perkins® 2506A-E15TAG1 | More |
Bore | 137.0 mm (5.4 in) 137.0 mm (5.4 in) | More |
Displacement | 15.2l (927.6 cu. in) 15.2l (927.6 cu. in) | More |
Stroke | 171.0mm (6.7 in) 171.0mm (6.7 in) | More |
Compression Ratio | 16.0:1 16.0:1 | More |
Governor Type | Electronic Electronic | More |
Files available to download
Features & Benefits
FG Wilson Diesel Engine
Perkins Engine
Alternator
Benefiting from a choice of leading alternators, the range incorporates the FG Wilson alternator as standard.
PowerWizard 1.1+
The FG Wilson PowerWizard range of digital control panels, combine straightforward menu navigation with advanced metering and protection technology. They are used in automatic mains failure applications in conjunction with transfer panels. Our PowerWizard range allows you to monitor and control your generator set with ease, whilst ensuring your unit operates within safe parameters and provides important diagnostic information when needed.
Design Criteria
Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Standby Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.
Single-Source Supplier
Fully prototype tested with certified torsional vibration analysis available
World Wide Product Support
FG Wilson manufactures product in the following locations: Northern Ireland • Brazil • China • India • USA With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network.
Equipment
P500-3 Standard Equipment
Engine
- Air Cleaner
- Lube oil drain valve
- Engine filled with lubrication oil
- High Coolant Temperature Shutdown
- Low Oil Pressure Shutdown
- Engine mounted battery charging alternator
Cooling
- Package mounted radiator
- Radiator fan and charging alternator guards
- Coolant Drain Valve
- Cooling System filled with Coolant mix
Exhaust
- Exhaust flange outlet
- Exhaust bellows and gasket
Fuel
- 8 Hr Fuel Tank
- BSP Fuel Sockets
Alternator
- FG Wilson
- SHUNT Excitation
- IP21 Protection
Control Panel
- PowerWizard 1.1+
Mounting
- Robust steel constructed base frame
- Base frame drag and lift points
- Captive linear vibration isolators between base and engine-generator
- Battery Tray and Cables
P500-3 Optional Equipment
Exhaust
- Industrial, Residential, Critical Silencers
Alternator
- Quadrature Droop Kit (AR6)
- Anti-Condensation Heater and Panel Circuitry (AH1)
- AREP / PMG excitation
- AVR Upgrades
- Three phase sensing
- Oversize Alternator
- Coastal ingress protection alternator
- Leroy Somer
Control Panels
- PowerWizard 2.1
- easYgen-2500
Starting/Charging
- Heavy duty dry battery
- Battery charger with auto boost
General
- Upgrade to Standard Set for “CE” Certification
- EEC Declaration of Conformity
- Dual wall base tank (8 hrs)
- Sound attenuated or High ambient enclosures
- Battery isolator switch